11.2. Erasing Scene Memory

S C E N E S E T T I N G

S A V E

S C E N E S E T T I N G

E R A S E

– – –

– – –

E R A S E

0 1

E R A S E

0 3

ENTER

3

ENTER

5

MEMORY

1

4

PARAMETER

Press for over 2 seconds.

2

PARAMETER

Step 1. Hold down the Memory key for 2 seconds or more.

The Scene memory setting screen is displayed.

Step 2. Use the Parameter setting knob to display "ERASE"

indication.

Step 3. Press the Enter key to display the Scene memory

erasure screen.

Step 4. Select with the Parameter setting knob the Scene

memory bank number (01 – 32) to be erased.

Step 5. Press the Enter key to erase the setting data stored in

the designated memory bank number.
After erasure completion, the unit returns to the
normal use state.