P. 58-c8), Display, P. 58-c9) – Vax M-9000 User Manual

Page 58: P. 58-c10), P. 58-c11), Selectable only when the remote controller type, P. 58-c10, Is set to zm-9001 or zm-9002

Advertising
background image

Displays the function assigned to the control output terminal.
The screen indications represent the following functions:

• NONE:

No function is assigned.

• POWER:

Power ON

• SCENE:

Scene memory recall

• CH ON:

Channel ON

• CH MUTE:

Channel mute

• EMG MUTE: Emergency mute activation (All output channel mute)
• PG OUT:

Paging activation

58

C O U T 0 1 I N F - N O N E

(C8) Control output terminal function display

(C9) Control output terminal status display
(when all are open)

C - O U T =

_ _ _ _ _ _ _ _ _ _ _ _

C - O U T =

1 2 3 4 5 6 7 8 9 A B C

(C9) Control output terminal status display
(when all are closed)

Status of all control output terminals can be confirmed on the screen, with the terminal Nos. 1 – 12 arranged in
numerical order from left to right.
When closed, the terminal number is indicated by alpha-numerals. Alphabet A represents the terminal number
10, B represents 11, and C represents 12.
An open terminal is indicated by an underscore "_".

Set the type of remote controller connected to the remote control input terminals.
Use the Left and Right shift keys to move the setting items on the screen.

• OFF:

Select this setting when no remote controller is connected.

• VOLUME: Select this setting when a normal variable resistor or variable DC power supply unit is connected.
• ZM-9001: Select this setting when the ZM-9001 is connected. This setting adds 6 control inputs. These

inputs are assigned the functions in the setting screens on

p. 69-E1

.

• ZM-9002: Select this setting when the ZM-9002 is connected. This setting adds 4 control inputs and 1

remote volume control. These inputs are assigned the functions in the setting screens on

p. 69-E1

.

REMOTE 1, REMOTE 2

OFF (default), VOLUME, ZM-9001, ZM-9002

Setting Range

Remote Volume Terminal Number

Controller type

(C10) Remote controller type setting

R E M O T E 1

V O L U M E

(C11) Remote-controlled channel setting
(when the remote controller type is set to VOLUME or ZM-9002)

R E M O T E 1

O U T P U T 1

Select the input or output channel of which volume you want to remotely control by using the control input
terminals on the rear panel or ZM-9002's volume control.
The REMOTE 1 on the screen represents the REMT VOL 1 of control input terminal, and the REMOTE 2
represents the REMT VOL 2.
Use the Left and Right shift keys to move the setting items on the screen.

REMOTE 1, REMOTE 2

OFF, INPUT 1 – 8, OUTPUT 1 – 2,
Max. OUTPUT 8 when T-001Ts are used
(default for REMOTE 1: OUTPUT 1, REMOTE 2:
OUTPUT 2)

Setting Range

Remote Volume Terminal Number

Remote-controlled channel