Input setting items, P. 40-a1), Input channel name setting – Vax M-9000 User Manual

Page 40: P. 40-a2), P. 40-a3), P. 40-a4), Input sensitivity setting

Advertising
background image

40

10.3.2. Input setting items

Unless otherwise specified, use the Parameter setting knob for each parameter selection.

(A1) Input gain setting

I N 1

– I N 1

O N

0

0

.

:

Select the input channel using the Input channel selection key.
Confirm the selection by setting the Input channel ON/OFF key to ON.
Set the input channel gain using the Input volume control.

I N 1 –

_ _ _ _ _ _ _

(A2) Input channel name setting

The flashing portion is the cursor position for entering channel name characters.
Select a character from the alphanumeric character list by rotating the Parameter setting knob, then move the
cursor with the Right shift key.
Entering a new name overwrites the existing name, if there is.
To delete the character, select [ _ ] (under-bar) with the Parameter setting knob. A space character cannot be
entered.
Up to 7 characters can be used to set the name.
Even when an input channel name has been set, some setting screens display the channel number, not the
set name.
When an input channel is stereo-linked (

p. 56-C1

), the name entry screen only for the odd channel is

displayed.

7 characters (default: IN1 – 8)

Setting Range

1 – 8 (default: 1)

ON (default), OFF

∞, –70.0 dB to +10.0 dB (default: 0.0 dB), 0.5 dB steps

Setting Range

Input Channel Selection

Channel Control

Channel Gain

I N 1 – P H A N T O M –

O F F

(A3) Phantom power ON/OFF setting
(when the D-001T is used or when the AN-001T is used and ANC operation is set to ACTIVE)

Set the Phantom power to ON or OFF.
The Phantom power cannot be set to ON for the stereo-linked input channel.

• ON: Supplies the phantom power.

• OFF: Does not supply the phantom power.

ON, OFF (default)

Setting Range

I N 1 – S E N S I T I V I T Y

– 1 0

(A4) Input Sensitivity setting
(when the D-001T is used or when the AN-001T is used and ANC operation is set to ACTIVE)

Select the input sensitivity from the following 9 levels depending on the input sources:

–60, –54, –48, –42, –36, –30, –24, –18, –10 dB (default)

Setting Range

Advertising