Control input function setting items, P. 69-e1, P. 69-e2) – Vax M-9000 User Manual

Page 69: P. 69-e4), P. 69-e5), Scene memory bank number selection, P. 69-e3), P. 69-e1)

Advertising
background image

69

10.7.2. Control input function setting items

Unless otherwise specified, use the Parameter setting knob for each parameter selection.

(E1) Control input function setting

C - I N 0 1 –

N O N E

Sets the functions to be assigned to the control input terminals or control buttons of the ZM-9001 or ZM-9002.

[When the function is set to LOADBANK]

(E2)
(When the control input function is set to LOADBANK)

C - I N 0 1 –

L O A D B A N K

Closing the control input terminal recalls the settings saved in a Scene memory bank number.
Assigning a function to the control input terminal or ZM-9001/9002's control button overwrites the previously
set function on it if there is.

(E3) Scene memory bank number selection

C - I N 0 1 – L O A D B A N K

0 1

Select the bank number to recall.

01 – 32 (default: 01)

Setting Range

C-IN01 to 12:

NONE (default), LOADBANK (Scene memory recall), VOLUP (volume
up), VOLDOWN (volume down), CH ON (channel ON), CH MUTE
(channel mute), EMG-MUTE (Cut-off by Emergency control), POWER
(Power ON/OFF remote control)

ZM-IN01 to 12: NONE (default), LOADBANK, VOLUP, VOLDOWN

Setting Range

[When the function is set to VOLUP or VOLDOWN]

C - I N 0 1 –

V O L U P

C - I N 0 1 –

V O L D O W N

(E4)
(When the control input function is set to VOLUP)

(E5)
(When the control input function is set to VOLDOWN)

Assign the volume-up or volume-down function to the control input.
Closing the control input terminal increases or decreases the volume of the set input or output channel.
Assigning a function to the control input terminal or ZM-9001/9002's control button overwrites the previously
set function on it if there is.

Advertising