Set the input channel to use the paging function.

65

10.6.3. Paging setting items

Unless otherwise specified, use the Parameter setting knob for each parameter selection.

(D1) Paging input channel setting

P A G I N G

O N

I N 1

IN1 – IN8 (default: IN1)

Setting Range

(D2) Trigger setting

(for the channel on which the module
other than the ZP-001T is used)

P A G I N G T R I G

C - I N

(D3) Trigger setting

(for the channel on which the ZP-001T
is used)

P A G I N G T R I G

Z P

Set the trigger to initiate paging. Type of trigger differs depending on the module that uses the channel.

• VOX: Voice Operated Exchange

Enables paging if the audio input signal exceeds a preset level. (When the D-001T is used)
When Trigger is set to VOX, be sure to also set the Gate function for the paging input channel to ON.

• C-IN: Enables paging while the control input terminal is closed.

• ZP:

Enables paging using the ZP-001T. (When the ZP-001T is used)

Modules except the ZP-001T and D-001T: C-IN (default)
D-001T: C-IN (default), VOX
ZP-001T: ZP (default)

Setting Range

(D4) Paging zone and Output channel settings

P A G I N G Z O N E

1 O U T 1

Paging zone

Output channel

Set the paging zone and output channel.

• With Trigger = VOX, only one zone can be set.

• With Trigger = C-IN, up to 4 zones can be set.

• With Trigger = ZP, the above screen is not displayed. Paging calls are output at the ZP-001T's output

channels selected by telephone dial operation.

Select the paging zone with the Parameter setting knob.
Then, select the output channel with the output channel selection key and set to ON (on-screen channel
number indicator lights) with the output channel ON/OFF key. By repeating this procedure, 2 or more channels
can be assigned to the paging zone.
Use the Right or Left shift key to move between the on-screen setting items.

1 – 4 (default: 1)

OUT1 – 2, Max. 8 when T-001Ts are used (default: OUT1)

Setting Range

Paging Zone

Output Channel

Advertising