Utility setting, Setting flow chart – Vax M-9000 User Manual

Page 55

Advertising
background image

Control input terminal function
display

(p. 57-C5)

C I N 0 1 I N F -

N O N E

C O U T 0 1 I N F - N O N E

Control output terminal function
display

(p. 58-C8)

S T E R E O L I N K

O U T 1 2

Stereo link setting

(p. 56-C1)

P A G I N G

O F F

Paging ON/OFF setting

(p. 56-C2)

N O M A T T E N U A T E

0

NOM attenuation setting

(p. 56-C3)

Control output terminal number
selection

(p. 57-C7)

C - O U T

0 1

N O N E

Control input terminal

C - I N

Control input terminal status
display

(p. 57-C6)

C - I N =

_ _ _ _ _ _ _ _ _ _ _ _

Control output terminal status
display

(p. 58-C9)

C - O U T =

_ _ _ _ _ _ _ _ _ _ _ _

S T E R E O

L I N K

Stereo link

Normal use state

P A G I N G

Paging

N O M

NOM

Control output function

C - O U T

M O D U L E

Module

Firmware version

V E R S I O N

M E M O R Y

Memory

Stereo link setting

Control input function setting

(p. 68)

Control output function setting

(P. 73)

Paging setting

(P. 64)

Communication speed

R S - 2 3 2 C

Communication speed (bps) setting

(p. 60-C20)

S E R I A L S P E E D =

5 7 6

.

Control input terminal number
selection

(p. 57-C4)

C - I N 0 1

N O N E

– – –

Password setting

(p. 60-C18)

S E T P A S S W O R D

_ _ _ _

GATE release time

G A T E

T I M E

GATE release time setting

(p. 60-C19)

G A T E

R E L E A S E T I M E

5

Key lock

K E Y L O C K

Lock status display

(p. 60-C17)

K E Y L O C K

U N L O C K E D

S L O T

1

=

O T H E R S

Slot number selection,
900 series module classification setting

(p. 60-C21)

Firmware version indication

(p. 61-C22)

F I R M

V E R S I O N = 1 1 0

.

I N I T I A L I Z E

O K ?

Memory initialization

(p. 61-C23)

Remote

R E M O T E

Remote controller type setting

(p. 58-C10)

R E M O T E 1

V O L U M E

Remote-controlled channel setting

(p. 58-C11)

R E M O T E 1

O U T P U T 1

(when the remote controller type is set to VOLUME
and ZM-9002)

A N C

ANC monitor

ANC monitor switching ON/OFF setting

(p. 59-C12)

A N C M O N

S E L E C T =

O N

Monitor switching control input terminal setting

(p. 59-C13)

(p. 59-C14)

(p. 59-C15)

(p. 59-C16)

(When the ANC monitor switching is set to ON)

M O N

S E L E C T

C I N 0 1

Interlock output control setting

M O N

S E L

S Y N C

O N

Interlock output terminal setting

Monitored ANC input channel selection

(When the interlock output control is set to ON)

S E L E C T S Y N C

C O U T 0 1

S E L E C T S Y N C

A N C 1

UTILITY

MEMORY

ENTER

ESC/BACK

Key lock function setting

(P. 77)

To determine,

ENTER

To determine,

ENTER

or

To cancel,

ESC/BACK

55

10.5. Utility Setting

10.5.1. Setting flow chart

The screen display examples shown below may differ from actual displays.
The on-screen indications shown in red here (actually shown by flashing cursors) are parameters or
setting contents to be selected with the Parameter setting knob, input channel selection key or other
designated keys.
The indications of the [ ], [ ], [

], and [

] arrows represent that the screen is switched with the

Screen shift key.
Unless otherwise specified, use the Parameter setting knob for each parameter selection.

Advertising