7.2. Optional Modules

7.2.1. D-001T (2-Channel Input Module)

Hot

Cold

Earth

Hot

Cold

Earth

1

2

D-001T

1

7.2.2. T-001T (Audio Output Expansion Module)

Hot

Cold

Earth

Hot

Cold

Earth

1

2

T-001T

2

1. Monaural input terminals [1, 2]

Electronically-balanced 3P removable terminal blocks.
Input level: –60 dB to –10 dB selectable.
Input impedance is 10 k

Ω when the phantom power is OFF, and

3 k

Ω when ON.

2. Monaural output terminals [1, 2]

Electronically-balanced 3P removable terminal blocks.
Output level:

0 dB

Output impedance: 600

For unbalanced connection, connect the unit's Hot and Earth
terminals to the connected equipment's Signal and GND
terminals, respectively. (Keep the unit's Cold terminal free.)

The D-001T module is designed for use with the 9000 Series amplifiers.
Up to 4 modules (8 channels in total) can be inserted into the amplifier.
The module can handle signals ranging from microphone level (–60 dB) to line level (–10 dB) in 9 input
sensitivity levels.
Phantom power (24 V) can be supplied for microphone level (–60 dB to –30 dB) signals.
The D-001T module has an internal digital signal processor that can process input signals.

The D-001T module is required to use a VOX (Voice Operated Exchange) function and input channel level
meter.

The T-001T module is designed for use with the 9000 Series amplifiers and can expand 2 output channels per
module.
Since the main unit has 2 fixed outputs, the audio output can be expanded to 8 channels by using a maximum
of 3 modules (6 channels).