Control outputs 1 – 4 – Vax M-9000 User Manual

Page 98

Advertising
background image

98

14.1.3. Control outputs 1 – 4

Use these terminals to activate LEDs, relays, and other external equipment.
Maximum operating current is 50 mA, and the maximum applicable voltage is +27 V.

REMT VOL1

(Remote volume 1)

REMT VOL2

(Remote volume 2)

IN

(Control inputs)

OUT

(Control outputs)

IN

E

IN

E

1

2

3

4

E

1

2

3

4

E

DC voltage
0 to 10 V

Applicable DC voltage
Max. 27 V DC

LEDs, Relays, etc. (Max. 50 mA)

or

Voltage control
10 k

Ω (linear-taper)

Contact closures,
Open collectors, etc.
(Open voltage: 3.3 V, Max. 1 mA)

(When a variable resistor or variable DC power supply unit is connected)

REMT VOL1

(Remote volume 1)

REMT VOL2

(Remote volume 2)

IN

E

IN

E

OUT

ZM-9001

E

Volume control

OUT

E

ZM-9002

(When the ZM-9001 or ZM-9002 is connected)

4

5

6

3

2

1

4

3

2

1

Note
One ZM-9001 or one ZM-9002
can be connected to each of the
REMT VOL1 and 2 terminals.

Advertising