P. 44-a16), Monitor on/off setting, P. 44-a17) – Vax M-9000 User Manual

Page 44: P. 44-a18), Lowest output level setting, P. 44-a19), Sampling time setting, P. 44-a21), P. 44-a20)

Advertising
background image

44

M O N I T O R O U T –

O F F

(A17) Monitor ON/OFF setting (when the AN-001T is used and ANC operation is set to ACTIVE)

Set to ON or OFF the monitor function that permits the ambient noise input signal to be output.

• ON: Outputs signals to be monitored.

• OFF: Does not output signals to be monitored.

ON, OFF (default)

Setting Range

M O N I T O R O U T –

O U T 1

(A18) Monitor output channel selection
(when the AN-001T is used, the ANC operation is ACTIVE, and the Monitor function is ON)

Select the output channel on which signals to be monitored are output.

OUT1 – 2, Max. 8 when T-001Ts are used (default: OUT1)

Setting Range

(A19) Lowest output level setting (when the AN-001T is used and ANC operation is set to ACTIVE)

M I N I M U M L E V E L

– 6

Set the lower limit of the ANC-activated output level.

–18, –15, –12, –9, –6 (default), –3 dB
Note: Settable level is 3 dB or more below the upper limit (highest output level).

Setting Range

M A X I M U M L E V E L

0

(A20) Highest output level setting (when the AN-001T is used and ANC operation is set to ACTIVE)

Set the upper limit of the ANC-activated output level.

–15, –12, –9, –6, –3, 0 (default) dB
Note: Settable level is 3 dB or more above the lower limit (lowest output level).

Setting Range

(A16) ANC-activated output setting (when the AN-001T is used and ANC operation is set to ACTIVE)

A N C A P P L I E S

O U T 1

Set on which output channel the ANC function works.

OUT1 – 2, Max. 8 when T-001Ts are used (default: OUT1)

Setting Range

S A M P L E T I M E

2 0

(A21) Sampling time setting (when the AN-001T is used and ANC operation is set to ACTIVE)

Set the required time to measure ambient noise. The ambient noise level is determined by being averaged over
the set measuring time. When the measuring time is long, the output level changes slowly with the ambient
level. However, the change in output level is not susceptible to a sudden change in ambient noise level.

10, 15, 20 (default), 30, 60, 120,180, 300 sec

Setting Range

Advertising