Environmental specifications, Physical specifications with projections, Regulatory approvals – Xantrex Technology MS2000 User Manual

Page 103: Fan operation, Regulatory approvals fan operation

Advertising
background image

Specifications

975-0125-02-01

A–5

Environmental Specifications

Table A-5 Environmental Specifications

Physical Specifications with Projections

Table A-6 Physical Specifications

Regulatory Approvals

Fan Operation

The internal cooling fans are automatic temperature-controlled.

The bottom fan is an exhaust fan and runs continuously.

Nominal Ambient temperature

77 °F (25 °C)

Full Power Operating Ambient
Temperature Range

–4 ° to 122 °F (–20 ° to 50 °C)

Maximum Operating Temperature

140 °F (60 °C)

Storage temperature range

–40 ° to 185 °F (–40 to 85 °C)

Humidity: Operation/Storage

95% RH, non-condensing

Length

16.19 inches (411 mm)

Width

14.20 inches (361 mm)

Height

8.17 inches (208 mm)

Weight

67 lbs (30 kg)

DC terminal bolt size

3/8 inch

Ground terminal bolt size

1/4 inch

Safety

CSA certified to CSA C22.2 No. 107.1 and UL 458 (including Marine
Supplement)

EMC

FCC Part 15B and Industry Canada Class B

Designed to ABYC recommended practices E-11 and A-25 for marine use

Important:

This internal temperature of the inverter/charger may be caused

by heat in the inverter/charger or by high ambient temperature.

Advertising