Power share, Equalize, Power share –12 equalize –12 – Xantrex Technology MS2000 User Manual

Page 66

Advertising
background image

Configuration

3–12

975-0125-02-01

Power Share

Configurable setting

Power Share is a configurable setting that you set to match to the breaker rating on
the AC input. This setting is used to ensure that the charger limits its output to try
to prevent nuisance tripping of the AC input breaker due to the total current drawn
by the charger and your other AC loads. See also “Power Share” on page 2–22.

When to use

Set the Power Share setting to match the AC input breaker. Use this setting when
connecting to an AC source. If using multiple AC sources via an AC transfer
switch, adjust this setting to the smaller AC breaker size.

Outcome

Setting the value higher than the AC source’s external breaker could cause the
external breaker to trip.

Equalize

Configurable setting

This setting lets you enable or disable charger equalization, only if the battery type
is flooded (or wet).

Equalization can be turned on (enabled) or off (disabled).

When to use

Review the section, “Operating in Equalization Mode” on page 2–18 before
adjusting this setting. This menu item is displayed if the battery type allows
equalization.

Power Share

[10A]

Range of values

Increment

Default

5 to 50 amps

5 amp increments

30 amps

Equalize

[Off]

Value

Default

On

Off

Off

Advertising