Invert power derating vs ambient temperature, Charger mode, Figure a-1 – Xantrex Technology MS2000 User Manual

Page 104

Advertising
background image

Specifications

A–6

975-0125-02-01

Invert Power Derating vs Ambient Temperature

The inverter/charger delivers up to 2000 watts continuous of sine wave output to
50 °C ambient temperature and 1500 watts continuous of sine wave output to 60
°C ambient temperature, derated linearly from 50 °C to 60 °C.

If the unit is in elevated ambient temperature above 50 °C, you are required to
reduce power draw according to the Figure A-1 to avoid over-temperature
shutdown.

Charger Mode

Total maximum charger output is 100 amps DC to 60 °C ambient. In higher
ambients, the main charger will automatically derate (reduce output current) to
maintain internal temperatures at a safe level.

Figure A-1 Inverter Output Power vs Ambient Temperature

-20

500

1000

1500

2000

-10

0

10

20

30

40

50

60

Ambient Temperature ( °C )