Sense interval, Cfg ac limits (configure ac limits), Chg stages – Xantrex Technology MS2000 User Manual

Page 77

Advertising
background image

Configuration

975-0125-02-01

3–23

Sense Interval

Configurable setting

This setting lets you adjust the interval of load sensing. The longer the interval,
the more power you will save. However, the longer intervals may cause delays in
the inverter power up and starting your loads.

Cfg AC Limits (Configure AC Limits)

Cfg AC Limits is a sub-menu. If selected, a list of sub-menu items appear. For
more information on this sub menu, Configure AC Limits, see page 3–25.

# Chg Stages

Full name

Number of charge stages

Configurable setting

These settings let you adjust the charger stages of your

house battery bank to

either two-stage charging or three-stage charging.

See

“Battery Charging

Reference for the Main Charger” on page B–1

for an explanation of two-stage and

three-stage charging.

Sense Interval

[1s]

Range of values

Increment

Default

1 second to 25
seconds

1 second

1 second

# Chg Stages

[3Stage]

Value

Default

2StgNoFloat

3Stage

3Stage

Important:

The Echo Charger is not affected by this setting.