Configuration

3–24

975-0125-02-01

Eqz Volts

Full name

Equalization voltage

Configurable setting

This setting lets you set the desired equalization voltage. This menu is displayed
only if charger equalization is enabled on the house battery bank.

Select a setting

based on the battery manufacturer’s recommendation. For more information, see
“Battery Charging Reference for the Main Charger” on page B–1.

Force Charge

Full name

Force Charge

Configurable setting

This setting forces the main charger to be enabled (On) whenever you have
qualified AC or reacquired qualified AC. If Force Enabled is not on, you must
turn it to On using the System Control Panel.

When to use

If you want the main charger to automatically start when you connect to qualified
AC input.

Outcome

The main charger starts whenever qualified AC input appears.

Eqz Volts

[15.5V]

Range of values

Increment

Default

13.5 to 15.5 VDC

0.1 volts

15.5 VDC

Important:

The Echo Charger is not affected by this setting.

Force Charge

[On]

Values

Default

On