Sub-menus, Lo dc volt, Batt type – Xantrex Technology MS2000 User Manual

Page 76: Batt size, Sense below, Sub-menus –22

Advertising
background image

Configuration

3–22

975-0125-02-01

Sub-Menus

Configure Inv/Chg Menu (Configure Inverter/Charger Menu)

Cfg/Inv Chg is a sub-menu. If selected, a list of sub-menu items appears.

Lo DC Volt

Full name

Low DC input voltage shutdown

Configurable setting

This setting lets you set the low voltage shutdown level for the inverter.

When to use

This setting limits the depth of discharge on your house battery bank.

Batt Type

See a description of this feature on page 3–15.

Batt Size

See a description of this feature on page 3–15.

Sense Below

Configurable setting

This setting lets you set the threshold for load sense power. This setting saves
battery consumption by keeping the inverter disabled (turned off) except when
load demand is present.

When to use

Adjust this setting to control the inverter based on the load.

Outcome

Sets the load threshold at a power level where you want the inverter to stay on, for
example, when a sufficient load is applied.

Lo DC Volt

[10.0V]

Range

Increment

Default

10 to 13 volts

0.1 volt

10 volts

Sense Below

[50W]

Range of values

Increment

Default

40 watts to 150 watts 10 watts

50 watts