Safe mode, Safe mode –8, Figure 2-4 – Xantrex Technology MS2000 User Manual

Page 38: Power save mode –8, Operate [advanced

Advertising
background image

Operation

2–8

975-0125-02-01

You can also enter or exit Power Save mode on the System Settings menu by
selecting Desired Mode and scrolling to PowerSave as shown in Figure 2-4.

Returning to
Operate mode

If an inverter/charger supplies power to the network, applying AC input with
utility power or generator power automatically returns the system to Operate
mode.

Safe Mode

Characteristics

Selecting Safe mode stops the generator (if it is running) and puts the System
Control Panel (and all Xanbus-enabled devices) into Safe mode. While in Safe
mode, the System Control Panel remains powered, “listening” to and reporting its
status to the network. However, the ouptut power of all Xanbus-enabled devices is
disabled and all inverting, charging, and generator starting activity stops. In Safe
mode, the MS2000 will not pass AC.

In Safe mode, the MS2000 continues to communicate, but the inverting and
charging functions are disabled.

When to use

Use Safe mode when you are adding or removing devices from the network.
Authorized service personnel must also put the System Control Panel in Safe
mode before performing software upgrades and diagnostics with the Xantrex
Diagnostic Tool.

If the System Control Panel is powered off while in Safe mode, it will be in Safe
mode when it is powered up again.

To return to Operate mode:

◆ On the System Settings menu, under Desired Mode, select “Operate.”

Figure 2-4 Power Save Mode

Operate

[Advanced]

CAUTION: Unexpected behavior

Before installing or removing a device on the network, put the network into Safe
mode. This prevents unexpected behaviour.

Advertising