Trap destination – 3Com CommWorks 5210 User Manual

Page 97

Advertising
background image

Execution Errors

97

Selected device is not a modem

The target slot is not a modem.

Channel number out of range: <number>

The target channel number is invalid for the particular type of card.

No DS0 assigned to modem. Test aborted.

The modem does not have a time slot assignment and tone test is therefore
impossible.

Extra targets, only the first will be used

The user selected more than one modem when invoking a tone test. The first
specified modem will be used, and the others ignored. (Warning only)

Extra command argument after target: <string>

Unused information was seen at the end of the command line and will be
ignored. (Warning only)

Receive ignores frequency/amplitude command arguments

Receive Tone was invoked with frequency/amplitude arguments, which will be
ignored. (Warning only)

Test in progress. Stop it before exiting?

Issued in a "Yes/No" dialog when user quits from window frame while a tone
test is in progress. (GUI, warning only)

Trap Destination

The following are the Trap Destination error messages and what they indicate.

Invalid IP address: <ip-addr>

The IP address entered is not a valid dot-notation IP address or host name in
the host database.

You must enter an IP Address!

When adding a trap destination, the user entered a blank IP address/host
name. (GUI only)

String ’invalid’ may not be used

The community string ’invalid’ is a reserved value and is not allowed to be
entered as data. (GUI only)

Community string too long. Truncate?

Issued in an "OK/Cancel" dialog when a community string and/or comment is
entered that is too long. (GUI, warning only)

Comment too long. Truncate?

Issued in an "OK/Cancel" dialog when a community string and/or comment is
entered that is too long. (GUI, warning only)

Advertising