Velleman HPS50 User Manual

Page 42

Advertising
background image

42

HPS50 PersonalScope

TM

Markers

Fig 34

1

2

Determining the frequency of a signal requires
the measurement of a period. The easiest way to
do this would be by placing the vertical markers
either on two consecutive peaks or two identical
slopes of a signal.

1. Press the “Marker 1-2”-key to view, select or

hide the markers. (1)

2. Press the cursur keys to move the markers. (2)

Notes:

• By pressing the ‘Marker 1-2’-key, you

select between marker 1 or 2. The screen
shifts automatically until the selected time
marker is on screen.

• At dynamic display mode (see display set-

up), the best display layout is chosen

depending the use of time markers or voltage
markers.

• Some meter readouts are replaced by the

marker readouts.

• Depending on the chosen display layout, not

all of the marker readouts can be displayed
at the same time.

• Removing the markers from the screen can

be done by repeatedly pressing the ‘Marker
1-2’
-key or by a short press of the ‘Display’-
key and using the up/down cursor keys.

Advertising