4. Inside Ladder Installation

30

PNEG-1802 Inside Ladder Instructions

4.00" Corrugated Commercial Grain Bin

Inside Ladder Installation (without Stir-Ator)

Inside Ladder Placement

The inside ladder package includes the ladder, starter brackets and double the amount of standoff
brackets as the outside ladder package. Begin by positioning the ladder directly under the manhole roof
panel as shown in

Figure 4X

and install the starter brackets as shown in

Figure 4Y on Page 31

. Place the

standoff brackets every 22" vertically on the sidewall sheets using the horizontal seam holes for every
other hole location. Use 5/16" x 3/4" bin bolts to attach the standoff brackets to the sidewall of the grain bin.

Figure 4X

Advertising