6 service power inserter (spi-lpe) – Alpha Technologies XM2-300CE-HP User Manual

Page 29

Advertising
background image

2.0

Installation, continued

2.6 Service Power Inserter (SPI-LPE)

To connect the coaxial cable

Before you remove the cover, unplug the SPI-LPE from the XM2-300HP.

1.

Remove the two screws holding the cover to the SPI-LPE chassis.

2.

Remove the SPI-LPE cover to expose the circuit board and seizure screw assembly.

3.

Insert the coaxial termination into the output port on the bottom of the SPI-LPE.

4.

Tighten the seizure screw to 35 inch-pounds.

5.

Fig. 2-4, Removing the Cover

2

3

1

Seizure Screw

Assembly

Fig. 2-5, Coaxial Cable Insertion and Securing

To prevent arcing, make certain the center conductor (stinger) of the coaxial termination is fully

seated inside the seizure screw assembly (5). Tighten to 35 inch-pounds.

CAUTION!

29

017-877-B1-001 Rev. A

Advertising
This manual is related to the following products: