4.4 Alarm Indications

In the event of a failure, the Active Alarm displays which alarms are active and how

to correct the alarm condition. Major alarms cause the red LED to flash (See Section

4.5).

Press UP or DOWN to stop Auto Scroll. Arrows on the right-hand side of the

display text indicate which keys to press to display the next menu item.
Press UP or DOWN to select the alarm of interest.

Press ENTER to select the alarm and display diagnostic information. Press

ESCAPE to return to the alarm list.

A Help sub-menu provides possible remedies relating to the active alarm. To access

the Active Alarm Help sub-menu, scroll to the alarm of interest and press ENTER.

The diagnostic information initially auto scrolls. To enter manual scroll mode, press

either UP or DOWN. Press DOWN to scroll through the list of remedies.

Alarms are classified in two categories:

MAJOR Alarms are indications of a serious failure within the XM2-300HP , such as

a loss of output voltage or a failed battery charger. Any situation that causes output

failure is considered a Major Alarm. Major alarms require immediate action to correct

the failure. To correct major alarms, follow the Smart Display on-screen instructions.

MINOR Alarms indicate a less serious failure, such as defective dual RTS or loss of

utility power. Corrective action can be delayed for a short time. To correct, follow the

Smart Display on-screen instructions.

The alarm matrices on the following pages indicate the MAJOR/MINOR active

alarms, the probable cause, and troubleshooting items to check to correct the alarm

condition.

If only one alarm is active, the alarm list is bypassed and diagnostic information for the single active alarm

displays.

NOTE: