4 menu structure and navigation, Legend – Alpha Technologies XM2-300CE-HP User Manual

Page 42

Advertising
background image

4.0

Operation, continued
4.3

Smart Display modes for XM2-300HP, continued

4.3.4 Menu Structure and Navigation

(from Operation Normal screen)

COMMS INFO

Float V/C = 2.27 V

TEST: 10 MIN

37.3 V

+

<ESC>

+

OPERATION NORMAL

SETUP MENU

CODE VER = 7.01.0

DEVICE ADDRESS= 1

ALPHACELL = OTHER

FLOAT V/C=2.27

ACCEPT V/C=2.40

TEMP COMP=5mV

BATT CAPACITY=100Ah

# BATT STRINGS*

BATT 1 DATE M/Y

BATT 2 DATE M/Y**

BATT 1 MHOS

BATT 2 MHOS**

MHO 1 DATE M/Y

MHO 2 DATE M/Y***

BATTERY 1 LIFE

BATTERY 1 AGE

BATTERY 2 LIFE**

BATTERY 2 AGE**

MHO’S MIN LEVEL

MHO’S MAJ LVL

STANDBY TIME=65M

STANDBY EVENTS=12

TOTAL RUN TIME = 365D

SELF TEST = OFF

TEST INTERVAL

TEST INHIBIT.

%DISCHARGE

TEST DURATION = 10M

TEST COUNTDOWN

FREQ RANGE = 3.0Hz

PIM OPTION = YES

RESET OUT 1

RESET OUT 2

OVER CURR 1 = 15.0A

OVER CURR 2 = 15.0A

RETRY DLY = 60s

RETRY LMT

OVER CURR TOL = 3000

SYSTEM FAN*

HEATER MAT*

PS PRIORITY*

TECHNICIAN ID*

INPUT LIMIT*

SET DEFAULTS

SELECT LANGUAGE

(Auto-Scroll Information)

OPER MODE = LINE

BATT STATUS

INV STATUS

DPM STATUS

INPUT VOLTAGE 120V

INPUT CURRENT

INPUT WATTS

OUTPUT VOLTAGE 89V

OUTPUT 1 CURR

OUTPUT 2 CURR

CHARGER MODE = FLOAT

BATT VOLTAGE 40.5V

BATTERY TEMP 37°C

ENCLOSURE TEMP

CHARGER CURRENT 8.2A

EST. BATT RUN

12 EVENTS 65 MIN

To Single-step

Back to Auto-Scroll

Back to

Auto-Scroll

OPER MODE = LINE

BATT STATUS

INV STATUS

DPM STATUS

INPUT VOLTAGE 120V

INPUT FREQUENCY 60Hz*

INPUT CURRENT

INPUT WATTS

OUTPUT VOLTAGE 89V

OUTPUT 1 CURR

OUTPUT 2 CURR

OUTPUT WATTS

OUTPUT VA 1060*

PERCENT LOAD 80%

CHARGER MODE = FLOAT

BATT VOLTAGE 40.5V

BATTERY TEMP 37°C

ENCLOSURE TEMP

CHARGER CURRENT 8.2A

EST. BATT RUN

12 EVENTS 65 MIN

*Only visible when in single-step mode

To Self-test

Self-test OFF

Back to Operation Normal

To COMMS INFO

Back to Operation Normal

COMMS INFO

(Single-step Information)

To Single-step

(Single-step Information)

SETUP MENU

(Single-step information)

(Auto-Scroll Information)

Operation Normal

Back Auto-Scroll

To

Program Mode

Selection returns to

Single-Step

Set-Up Menu

To Accept New Data

To Accept New Data

To Abort

Edit using

LEGEND

Control

Panel

Key

Display

Symbol

Description

UP Arrow

DOWN Arrow

ESCAPE

ENTER

BATT.SPANNUNG

(Auto-Scroll Information)

To Single-step

Back to Auto-Scroll

Back to Single-step

Setup Menu

LANGUAGE =

ENGLISH

SPANISH

FRENCH

GERMAN

CM = 00:90:EA:12:34:56

CPE = 00:90:EA:12:34:57*

CM = 192.168.123.123

CPE = 192.168.123.124*

CM Rx PWR = -12.9 dBmV

CM Tx PWR = 34.5 dBmV

DN FREQ = 300.000 MHz

UP FREQ = 15.000 MHz

MODEL = DPM

SW = xx.xx.xx.xx

CM = 00:90:EA:12:34:56

CPE = 00:90:EA:12:34:57*

CM = 192.168.123.123

CPE = 192.168.123.124*

CM Rx PWR = -12.9 dBmV

CM Tx PWR = 34.5 dBmV

DN FREQ = 300.000 MHz

UP FREQ = 15.000 MHz

MODEL = DPM

SW = xx.xx.xx.xx

* only shown in

Dual-IP configurations

220GOLD

220HPL-FT

220GXL

210GXL

195GXL

195GOLD

180GXL

165GXL

115HPL-FT

85GXL

70HPL-FT

CODEVER = 7.01.0

DEVICE ADDRESS = 1

ALPHACELL=OTHER

FLOAT V/C = 2.27

ACCEPT V/C = 2.40

TEMP COMP=5mV

BATT CAPACITY = 100Ah

BATTERY1 DATE

BATTERY1 MHOS

MHO1 DATA

BATTERY1 LIFE

BATTERY1 AGE

MHO’s MIN LVL

MHO’s MAJ LVL

STANDBY TIME=65M

STANDBY EVENTS=12

TOTAL RUN TIME=365D

SELF TEST = OFF

TEST INTERVAL

TEST INHIBIT

% DISCHARGE

TEST DURATION = 10M

TEST COUNTDOWN

FREQ RANGE = 3.0Hz

PIM OPTION = YES

RESET OUT 1

RESET OUT 2

OVERCURRENT1 = 15.0A

OVERCURRENT2 = 15.0A

RETRY DELAY = 60S

RETRY LIMIT = 20

OVERCURRENT TOL = 3000

SYSTEM FAN

HEATER MAT

PS PRIORITY

TECH ID

INPUT I LIMIT

SET DEFAULTS = NO

SELECT LANGUAGE

Pressing ENTER enables

the user to select the AlphaCell

battery in the system.

Values for Float, Accept,

Temp Comp and Battery

Capacity are automatically

selected.

**Visible when “Number of Battery

Strings” is set to 2.

*Visible in Single-step

To Setup Menu

42

017-877-B1-001 Rev. A

Advertising