Fig. 4-5, Comms Info Display

(Examples are given for values in the display)

4.0

Operation, continued
4.3

Smart Display modes for XM2-300HP, continued

4.3.2 Comms Information Display (with DPM)

Pressing ENTER while in the Operation Normal screen will open the Comms

Information display (only displayed when paired with DPM, otherwise display will

read “NO DATA”). This mode operates in a similar fashion as the Operation Normal

display. When you first access the information display, information displays in Auto

Scroll mode. Press UP or DOWN to access information one step at a time. Press

ENTER to access the Setup Menu (discussed in Section 4.3.3, Setup Menu). Press

ESCAPE to reactivate Auto Scroll mode. Press ESCAPE a second time to reactivate

Operation Normal mode (up one level).

The Comms Information display contains the following items:

COMMS INFO

CM

00:90:EA:12:34:56

CPE

00:90:EA:12:34:57

CM

192.168.123.123

CPE

192.168.123.124

CM RX PWR

-12.9 DBMV

CM TX PWR

34.5 DBMV

DN FREq

300.000 MHz

UP FREq

15.000 MHz

MODEL

DPM

SW

XX.XX.XX.XX

Top line
Second line

The top line provides additional instructions. Use the arrows to manually scroll.

The second line cycles through the parameters listed above.

*

Only visible in dual-IP configurations

*

*

DPM Firmware

Version; change

location in menu