DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual

Page 10

Advertising
background image

10

IM-pAC Getting Started Guide

www.camcoindex.com | www.destaco.com

Issue Number: 5

A standard Right Angle unit with cam and limit or proximity switch mounted on the

housing has a correct keyway position directly opposite the cam lobe. The cam and

switch may also be mounted on the reducer.

A standard Parallel unit with cam and limit or proximity switch mounted on the housing

has a correct keyway position directly opposite the output shaft, 90 degrees clockwise

from the cam lobe. The cam and switch may also be mounted on the reducer.

1.17

Drive default parameter list for a single preset speed appli-
cation

a) Default parameters are for motor 92C49952070000 1/3 hp. 230 V 60 hz motor. See

motor name plate.

NOTE

Advertising