5 access, 6 compliance and regulations, 7 motor – DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual

Page 33: 8 adjusting parameters, 9 electrical installation, Access, Compliance and regulations, Motor, Adjusting parameters, Electrical installation

Advertising
background image

IM-pAC Getting Started Guide

33

Issue Number: 5

www.camcoindex.com | www.destaco.com

Re

ad

Me
F

irs

t

Instr
ucti

on

s

S

a

fe

ty In

fo

rm

at

io

n

Ra

tin

g Da

ta

Me
ch

an

ica

l

Inst
al

lati

on

Ele

ctrica
l Inst
alla

tio

n
Ke

yp

ad

an

d

D

ispl

ay

Par

am
eter
s

D

iag

no

stics

UL
Li

sti

ng

Info
rm

atio

n

2.5

Access

Access must be restricted to authorized personnel only. Safety regulations which apply

at the place of use must be complied with.
The IP (Ingress Protection) rating of the drive is installation dependant.

2.6

Compliance and regulations

The installer is responsible for complying with all relevant regulations, such as national

wiring regulations, accident prevention regulations and electromagnetic compatibility

(EMC) regulations. Particular attention must be given to the cross-sectional areas of

conductors, the selection of fuses and other protection, and protective ground (earth)

connections.
The IM-pAC Technical Data Guide contains instructions for achieving compliance with

specific EMC standards.
Within the European Union, all machinery in which this product is used must comply

with the following directives:

98/37/EC: Safety of machinery
89/336/EEC: Electromagnetic compatibility

2.7

Motor

Ensure the motor is installed in accordance with the manufacturer's recommendations.

Ensure the motor shaft is not exposed.
Standard squirrel cage induction motors are designed for single speed operation. If it is

intended to use the capability of a drive to run a motor at speeds above its designed

maximum, it is strongly recommended that the manufacturer is consulted first.
Low speeds may cause the motor to overheat because the cooling fan becomes less

effective. The motor should be installed with a protection thermistor. If necessary, an

electric force vent fan should be used.
The values of the motor parameters set in the drive affect the protection of the motor.

The default values in the drive should not be relied upon.
It is essential that the correct value is entered into parameter 06, motor rated current.

This affects the thermal protection of the motor.

2.8

Adjusting parameters

Some parameters have a profound effect on the operation of the drive. They must not

be altered without careful consideration of the impact on the controlled system.

Measures must be taken to prevent unwanted changes due to error or tampering.

2.9

Electrical installation

2.9.1

Electric shock risk

The voltages present in the following locations can cause severe electric shock and may

be lethal:

AC supply cables and connections

DC bus, dynamic brake cables and connections

Output cables and connections

Many internal parts of the drive, and external option units

Unless otherwise indicated, control terminals are single insulated and must not be

touched.

Advertising