2 parameter descriptions - level 2, Parameter descriptions - level 2 – DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual

Page 57

Advertising
background image

IM-pAC Getting Started Guide

57

Issue Number: 5

www.camcoindex.com | www.destaco.com

Re

ad

Me
F

irs

t

Instr
ucti

on

s

Sa

fety
Info
rm

atio

n

R

ati

ng

D

ata

Me
ch

an

ica

l

Inst
al

lati

on

El

ec

tric

al

In

stal

la

tion
Ke

yp

ad

a

nd

Dis
pla

y

Pa
ram

e

te

rs

D

iag

no

stics

UL
Li

sti

ng

Info
rm

atio

n

L1

: Level 1 access - only the first 10 parameters can be accessed

L2

: Level 2 access - All parameters from 01 to 60 can be accessed

L3

: Level 3 access - All parameters from 01 to 95 can be accessed

LoC

: Used to lock a security code in the drive. See section 6.6 Security codes on

page 48 for further details.

7.2

Parameter descriptions - Level 2

diS

: Mechanical brake software disabled

rEL

: Mechanical brake software enabled. Brake control via relay T5 & T6. The digital

output on terminal B3 is automatically programmed as a drive ok output.

d IO

: Mechanical brake software enabled. Brake control via digital output B3. The relay

outputs on terminals T5 and T6 are automatically programmed as a drive ok

output.

USEr

:Mechanical brake software enabled. Brake control to be programmed by user.

The relay and digital output are not programmed. The user should programme the

brake control to either the digital output or relay. The output not programmed to

the brake control can be programmed to indicate the required signal.

See Pr 46 to Pr 51 on page 63.

No

Function

Range

Defaults

Type

10

Parameter access

L1, L2, L3, LoC

2:L3

RW

No

Function

Range

Defaults

Type

11

Start/Stop logic select

0 to 6

0

RW

Pr 11

Terminal B4

Terminal B5

Terminal B6

Latching

0

Enable

Run Forward

Run Reverse

No

1

Not Stop

Run Forward

Run Reverse

Yes

2

Enable

Run

Forward / Reverse

No

3

Not Stop

Run

Forward / Reverse

Yes

4

Not Stop

Run

Jog

Yes

5

User programmable Run Forward

Run Reverse

No

6

User Programmable User Programmable User Programmable User Programmable

A change to Pr 11 is set by pressing the MODE key on exit from parameter edit mode.

The drive must be disabled, stopped or tripped for a change to take place. If Pr 11 is

changed while the drive is running, when the

MODE key is pressed on exit from

parameter edit mode, Pr 11 will change back to its previous value.

NOTE

M

M

No

Function

Range

Defaults

Type

12

Brake controller enable

diS, rEL, d IO, USEr

0:diS

RW

A change to Pr 12 is set by pressing the MODE key on exit from parameter edit mode.

The drive must be disabled, stopped or tripped for a change to take place. If Pr 12 is

changed while the drive is running, when the

MODE key is pressed on exit from

parameter edit mode, Pr 12 will change back to its previous value.

NOTE

M

M

Great care should be taken when implementing a brake control set-up, as this may cause

a safety issue depending on the application, e.g. crane. If in doubt, contact the supplier

of the drive for further information.

WARNING

Advertising