7 wiring power and switches to drive, Wiring power and switches to drive – DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual

Page 7

Advertising
background image

IM-pAC Getting Started Guide

7

Issue Number: 5

www.camcoindex.com | www.destaco.com

Re
a

d

M
e

F

ir

s

t

In

st

ru

ct

io

ns

Sa

fety
Info
rm

atio

n

R

ati

ng

D

ata

Me
ch

an

ica

l

Inst
al

lati

on

Ele

ctrica
l Inst
alla

tio

n
Ke

yp

ad

an

d

D

ispl

ay

Par

am
eter
s

D

iag

no

stics

UL
Li

sti

ng

Info
rm

atio

n

1.6

Motor Jumper

Configuration for 1/3 hp and 1.00 hp

motors

1.7

Wiring Power and Switches to Drive

1. Refer to Chapter 3 Rating Data for all other fuse sizes and control and motor cable

wire sizes. Single phase can be obtained from a 3 phase "wye" by wiring two of the

"hots" (L1 and L2 or L2 and L3 or L1 and L3) to the drive. Do not remove internal

EMC filter. See Chapter 5.

2. The control terminal B2 outputs 24 volts DC and will be used to power the signals.

The control terminal B4 is used to enable the drive. As long as B2 and B4 are

connected the drive will run. Use a normally closed switch (not supplied by IMC) or

jumper between B2 and B4 to enable the drive. The control terminal B5 runs the

motor forward and B6 runs the motor in reverse. If the indexer is not turning in the

proper direction interchange B5 and B6.

3. Make sure the indexer is in the middle of its dwell position before starting or

stopping the motor. see section 1.16 Indexer drive shown in middle of dwell
position diagram.

on page 9.

4. The motor is made to run by closing the B2-B5 or B2-B6 terminals. Opening them

will stop the motor.

5. Cycling on demand using a limit switch and inverter duty motor. The normally closed

side of the cam shaft limit switch should be wired to terminals B2 and B5 (or B6).

When the indexer is in dwell the switch will be open. A start signal is sent by

momentarily closing B2 and B5 with an external switch. As the camshaft is turning

the limit switch on the cam shaft will close and thus maintain the B2-B5 (or B6)

closure. When the indexer enters dwell the trip cam on the cam shaft will cause the

limit switch to open the B2-B5 (or B6) connection and stop the motor.

Diagram for wiring switches to the IM-pAC control terminals (cover has been removed)

for cycling on demand using a limit

switch, momentary start and inverter duty motor.

Index drive is in middle of dwell position see section 1.16 Indexer drive shown in middle
of dwell position diagram.

on page 9.

W2 U2

V2

U1

V1

W1

230V

W2 U2

V2

U1

V1

W1

400-460V

L1

L2

L3

L1

L2

L3