DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual

Page 60

Advertising
background image

60

IM-pAC Getting Started Guide

www.camcoindex.com | www.destaco.com

Issue Number: 5

no

: defaults are not loaded

Eur

: 50Hz default parameters are loaded

USA

: 60Hz default parameters are loaded

Default parameters are set by pressing the

MODE key on exit from parameter edit

mode after Pr 29 has been set to Eur or USA.

When default parameters have been set, the display will return to Pr 01 and Pr 10 will be

reset to L1.

0

: Fast ramp selected

1

: Standard ramp with normal motor voltage selected

2

: Standard ramp with high motor voltage selected

3

: Fast ramp with high motor voltage selected

Fast ramp is linear deceleration at programmed rate, normally used when a braking

resistor is installed.
Standard ramp is controlled deceleration to prevent DC bus over-voltage trips, normally

used when there is no braking resistor installed.
If a high motor voltage mode is selected, deceleration rates can be faster for a given

inertia but motor temperatures will be higher.

0

: Coast to stop selected

1

: Ramp to stop selected

2

: Ramp to stop with 1 second DC injection braking

3

: DC injection braking with detection of zero speed

4

: Time DC injection braking

OFF

:Fixed linear voltage to frequency ratio (constant torque - standard load)

On

: Voltage to frequency ratio dependant on load current (dynamic/variable torque/

load). This gives a higher motor efficiency.

0

: Disabled

1

: Detect positive and negative frequencies

2

: Detect positive frequencies only

3

: Detect negative frequencies only

If the drive is to be configured in fixed boost mode (Pr 41 = Fd or SrE) with catch a

spinning motor software enabled, an autotune (see Pr 38 on page 62) must be carried

out to measure the motor’s stator resistance beforehand. If a stator resistance is not

No

Function

Range

Defaults

Type

29

Load defaults

no, Eur, USA

0:no

RW

M

The drive must be in a disabled, stopped or tripped condition to allow default parameters

to be set. If default parameters are set while the drive is running, the display will flash

FAIL once before changing back to no.

NOTE

No

Function

Range

Defaults

Type

30

Ramp mode select

0 to 3

3:FSt.Hv

RW

No

Function

Range

Defaults

Type

31

Stop mode select

0 to 4

1

RW

No

Function

Range

Defaults

Type

32

Dynamic V to f select

OFF or On

OFF

RW

No

Function

Range

Defaults

Type

33

Catch a spinning motor select

0 to 3

0

RW