1.18

Drive parameter list for using a potentiometer to control
speed

Pr 37

Maximum switching

frequency

12

kHz

Pr 38

Auto-tune

0

Pr 39

Motor rated frequency

60

Hz (from motor plate)

Pr 40

Number of motor poles

2:4 pole

Pr 41

Voltage mode select

2:Fd

Pr 42

Low frequency voltage

boost

4

Pr 43

Serial comms baud rate

19.2

Pr 44

Serial comms address

1

Pr 45

Software version

1.04

Pr 46

Brake release current

threshold

50

Pr 47

Brake apply current

threshold

10

Pr 48

Brake release frequency

1

Hz

Pr 49

Brake apply frequency

2

Hz

Pr 50

Pre-brake release delay

0

s

Pr 51

Post brake release delay

0

s

Parameter

Description

Value

Units

The speed range of the potentiometer is from 0 to the Pr 02 value.

NOTE

Parameter

Description

Value

Units

Pr 01

Minimum set speed

0

Hz

Pr 02

Maximum set speed

60

Hz

Pr 03

Acceleration rate 1

0.1

s/100Hz

Pr 04

Deceleration rate 1

0.2

s/100Hz

Pr 05

Drive configuration

1:Av.Pr

Pr 06

Motor rated current

-

A (from motor plate)

Pr 07

Motor rated full load rpm

0

RPM (always 0)

Pr 08

Motor rated voltage

-

V (from motor plate)

Pr 09

Motor rated power factor

-

(from motor plate)

Pr 10

Security status

0:L1

Pr 11

Start / stop logic select

0

Pr 12

Brake controller enable

0:dis

Pr 15

Jog reference

1.5

Hz

Pr 16

Analog input 1 mode

(terminal T2)

6:VoLt

Pr 17

Allow negative

references

OFF

Pr 18

Preset speed 1

0

Hz

Pr 19

Preset speed 2

0

Hz

Pr 20

Preset speed 3

0

Hz

Pr 21

Preset speed 4

0

Hz

Pr 22

Load display units

Ld

Advertising