Figure 7-10 Pr 05 = HVAC terminal configuration

Enter the motor current rating (taken from the motor name plate).
The drive rated current is the 100% RMS output current value of the drive. This value

can be set to a lower value but not to a higher value than the drive rated current.

Enter the rated full load speed of the motor (taken from the motor name plate).
The motor rated speed is used to calculate the correct slip speed for the motor.

Enter the motor rated voltage (taken from the motor name plate).

This is the voltage applied to the motor at base frequency.

Enter the motor rated power factor cos ϕ (taken from the motor name plate).

0V

Remote current speed

reference input (A1)

+10V reference output

Not used

+24V output

Drive enable / reset

Run reverse

Reference

select

Remote speed

reference input

V

_

+

Eur + USA

Analog output

(motor speed)

Digital output

(zero speed)

T1

T2

T3

T4

B1

B2

B3

B4

B5

B6

B7

+24V

0V

Auto

run

Hand/Off/Auto

switch

H

A

A

Run forward

H: Contacts made in 'hand' position -

Keypad control

A: Contacts made in 'auto' position -

Remote current speed reference input

No

Function

Range

Defaults

Type

06

Motor rated current

0 to Drive rated current A

1.14

RW

Pr 06 Motor rated current must be set correctly to avoid a risk of fire in the event of a

motor overload.

WARNING

No

Function

Range

Defaults

Type

07

Motor rated speed

0 to 9999 rpm

0

RW

A value of zero entered into Pr 07 means slip compensation is disabled.

NOTE

If the full load speed of the motor is above 9999rpm, enter a value of 0 in Pr 07. This will

disable slip compensation as values >9999 cannot be entered into this parameter.

NOTE

No

Function

Range

Defaults

Type

08

Motor rated voltage

0 to 240, 0 to 480 V

230

RW

If the motor is not a standard 50 or 60Hz motor, see Pr 39 on page 62 and adjust accordingly.

NOTE

No

Function

Range

Defaults

Type

09

Motor power factor

0 to 1

0.74

RW