DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual

Page 36

Advertising
background image

36

IM-pAC Getting Started Guide

www.camcoindex.com | www.destaco.com

Issue Number: 5

Output frequency:

0 to 1500Hz

Output voltage:

3 phase, 0 to drive rating (240 or 480Vac maximum set by Pr 08).

Table 3-4

The output voltage can be increased by 20% during deceleration. See Pr 30 on page 60

NOTE

The maximum continuous current inputs are used to calculate input cable and fuse

sizing. Where no maximum continuous input currents are indicated, use the typical full

load input current values.

NOTE

IMC Part Number

Phases ph

Fuse

Input cable

Motor cable

1

3

1ph

3ph

AWG

mm

2

AWG

mm

2

92C85797010000

x

N/A

16

N/A

14

1.5

16

1

92C85797020000

N/A

x

N/A

6

16

1

16

1

92B90482010000

x

x

16

10

12 / 14

2.5 / 1.5

16

1

92B90482020000

x

x

20

16

12 / 14

2.5 / 1.5

16

1

92B90482030000

x

x

25

20

10 / 12

4.0 / 2.5

14

1.5

92B90482040000

N/A

x

N/A

10

16

1

16

1

92B90482050000

N/A

x

N/A

16

14

1.5

16

1

92B90482060000

N/A

x

N/A

16

12

2.5

14

1.5

92B90482070000

x

N/A

25

N/A

10

4

16

1

92B90482080000

x

N/A

32

N/A

10

4

16

1

92B90482090000

N/A

x

N/A

6

16

1

16

1

The two cable sizes for 92B90482010000, 92B90482020000 and 92B90482030000

refer to 1 and 3 phase values respectively.

NOTE

Advertising