1.22

Drive parameter list for using a PLC to control speed

10 Vdc applied to T1 and T2 will run the motor to the Pr 02 Maximum set speed. The

speed is proportional to the applied voltage.

NOTE

Parameter

Description

Value

Units

Pr 01

Minimum set speed

0

Hz

Pr 02

Maximum set speed

60

Hz

Pr 03

Acceleration rate 1

0.1

s/100Hz

Pr 04

Deceleration rate 1

0.2

s/100Hz

Pr 05

Drive configuration

2:AI.Pr

Pr 06

Motor rated current

-

A (from motor plate)

Pr 07

Motor rated full load rpm

0

RPM (always 0)

Pr 08

Motor rated voltage

-

V (from motor plate)

Pr 09

Motor rated power factor

-

(from motor plate)

Pr 10

Security status

0:L1

Pr 11

Start / stop logic select

0

Pr 12

Brake controller enable

0:dis

Pr 15

Jog reference

1.5

Hz

Pr 16

Analog input 1 mode

(terminal T2)

6:VoLt

Pr 17

Allow negative

references

OFF

Pr 18

Preset speed 1

0

Hz

Pr 19

Preset speed 2

0

Hz

Pr 20

Preset speed 3

0

Hz

Pr 21

Preset speed 4

0

Hz

Pr 22

Load display units

Ld

Pr 23

Speed display units

0:Fr

Pr 24

Customer defined scaling

1

Pr 25

User security code

0

Pr 27

Power-up keypad

reference

0

Pr 28

Parameter cloning

0:no

Pr 29

Load defaults

0:no

Pr 30

Ramp mode select

3:FSt.Hv

Pr 31

Stopping mode select

1

Pr 32

Dynamic V to f select

OFF

Pr 33

Catch a spinning motor

select

0

Pr 34

Terminal B7 mode select

0:dig

Pr 35

Digital output control

(terminal B3)

0:n=0

Pr 36

Analog output control

(terminal Bi)

0:Fr

Pr 37

Maximum switching

frequency

12

kHz

Pr 38

Auto-tune

0

Pr 39

Motor rated frequency

-

Hz (from motor plate)

Pr 40

Number of motor poles

2:4 pole