Step 1 - Changing the security level.
Press the M (memory) button on the key pad. The display will start to show the flashing

parameter numbers on the left side and the non-flashing parameter values on the right

side. Now, press the /\ button to the right of the M button several time until the left

parameter value changes to 10. If you happen to go passed Pr 10 then use the \/ key to

return to Pr 10. Once you are at the flashing Pr 10, press the M key and the parameter

value on the right L1 should start to flash.
Press the /\ key 2 times until a value of L3 appears [10 L3].
Press the M key 2 times to return the display back to [ih 0.0].

Step 2 - How to map the motor thermal constant to Pr 61.
Press the M button on the key pad. Now, press the \/ button until the left parameter

value changes to Pr 71. If you happen to go passed Pr 71, then use the /\ key to return

to Pr 71. Once you are at the flashing Pr 71, press the M key and the parameter value

on the right 0.0 should start to flash.
Press the /\ key several times until a value of 4.15 appears [71 4.15].
Press the M key 2 times to return the display back to the [ih 0.0].

Step 3 - How to map the symmetrical current value to Pr 62.
Press the M button on the key pad. Now, press the \/ button until the left parameter

value changes to Pr 72. If you happen to go passed Pr 72, then use the /\ key to return

to Pr 72. Once you are at the flashing Pr 72, press the M key and the parameter value

on the right 0.0 should start to flash.
Press the /\ key several times until a value of 4.07 appears [72 4.07].
Press the M key 2 times to return the display back to [ih 0.0].

Step 4 - How to view the current magnitude for your application.
See the Safety Warning on the first page before continuing.
The key pad display should show [rd 0.0] when you start. If the display shows [ih 0.0]

you must take the control out of inhibit mode by closing B2 and B4. Make sure you are

set to run at your intended speed and load. You will now run the motor continuously in

order to view and record the maximum current demand for your application. In order to

run the motor continuously you must keep connection B2 and B5 closed. You can do

this with a simple jumper. Once the motor and drive are running, press the M button on

the key pad. Now, press the \/ button until the left parameter value changes to Pr 88. If

you happen to go passed Pr 88, then use the /\ key to return to Pr 88. The maximum

value for Pr 88 is the maximum value for your application. You will use this amperage

value in step 6 as part of a calculation for the symmetrical current value.
Press the M key 2 times to return the display back to the [rd 0.0].
You can now remove the jumper between B2 and B5.

Step 5 - How to change the motor thermal constant Pr 61.
Press the M button on the key pad. Now, press the \/ button several times until the left

parameter value changes to Pr 61. If you happen to go passed Pr 61, then use the /\

key to return to Pr 61. Once you are at the flashing Pr 61, press the M key and the

parameter value on the right Pr 89 should start to flash.
Press the \/ key several times until a value of 1 appears [61 1].
Press the M key 2 times to return the display back to the [ih 0.0].