7.3

Parameter descriptions - Level 3

Set Pr 71 to Pr 80 to the required advanced parameter number to be accessed.
The value within these parameters will be displayed in Pr 61 to Pr 70. Pr 61 to Pr 70 can

then be adjusted to change the value within a parameter.

7.4

Diagnostic parameters

The following read only (RO) parameters can be used as an aid to fault diagnosis on the

drive. See Figure 8-1 Diagnostics logic diagram on page 68.

No

Function

Range

Defaults

Type

71

to

Pr

61

to Pr

70

set up

0 to Pr 21.51

RW

80

No

Function

Range

Type

81

Frequency reference selected

±Pr 02 Hz

RO

82

Pre-ramp reference

±Pr 02 Hz

RO

83

Post-ramp reference

±Pr 02 Hz

RO

84

DC bus voltage

0 to Drive maximum VDC

RO

85

Motor frequency

±Pr 02 Hz

RO

86

Motor voltage

0 to Drive rating V

RO

87

Motor speed

±9999 rpm

RO

88

Motor current

+Drive maximum A

RO

89

Motor active current

±Drive maximum A

RO

90

Digital I/O read word

0 to 95

RO

91

Reference enabled indicator

OFF (0) or On (1)

RO

92

Reverse selected indicator

OFF (0) or On (1)

RO

93

Jog selected indicator

OFF (0) or On (1)

RO

94

Analog input 1 level

0 to 100 %

RO

95

Analog input 2 level

0 to 100 %

RO

Advertising