8 programming, 9 speed control, Programming – DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual

Page 8: Speed control

Advertising
background image

8

IM-pAC Getting Started Guide

www.camcoindex.com | www.destaco.com

Issue Number: 5

1.8

Programming

The IM-pAC drive is delivered to you programmed for the 1/3 hp 230V 60 hz motor (IMC

Pt. No 92C49952070000). For a different motor rated frequency, amperage, voltage or

power factor you must change the motor parameters Pr 39, Pr 06, Pr 08 and Pr 09.

Below is a chart of the values for all the possible configurations of the standard IMC

motors. If you are not using an IMC motor then you must read these values from the
motor name plate

. See section 6.3 Selecting and changing parameters on page 47 for

how to edit the parameter values.

1.9

Speed Control

You must now determine how you wish to control the maximum speed for your

application.
You can use a single preset speed parameter, or use an external potentiometer, or use

a potentiometer and 3 other preset speeds, or use a PLC to control speed. Please refer

to one of the four parameter list sections for the additional parameter changes for the

speed control you require for your application.

T1

T2

T3

T4

T5

T6

B1

B2

B3

B4

B5

B6

B7

Drive enabled (normally closed)

Stop signal switch on camshaft

(normally closed)

Momentary Start

Radio Shack Pt.No 275-324

IMC Pt.No 87C08062019510

Radio Shack Pt.No 275-609

hp

kw

IMC Motor

Frequency

Pr 39

hz

Current

Pr 06

amp

Rpm

Pr 07

Voltage

Pr 08

volt

Power

factor

Pr 09

cos

0.33

0.25

92C49952070000

60

1.14

0

230

0.74

0.33

0.25

92C49952070000

60

0.57

460

0.74

0.33

0.25

92C49952070000

50

1.14

200

0.74

0.33

0.25

92C49952070000

50

0.57

400

0.74

1.00

0.75

92C49955410000

60

3.15

230

0.79

1.00

0.75

92C49955410000

60

1.9

460

0.66

1.00

0.75

92C49955410000

50

3.65

200

0.70

1.00

0.75

92C49955410000

50

2.1

400

0.70

Never auto tune the motor

WARNING

Advertising