PAGE 6-39

enFORCE

Operation Manual

¾

Data Number 13 - Standard Load

ƒ

In Load Control Methods, this is the target load value.

(Example: If Standard Load is 10KN, press will attempt to operate until 10KN is
achieved.)

A setting is possible from 0 to 105% of full-scale value.

¾

Data Number 14 - Speed Change Load

ƒ

The load value at which press speed will change to [53: Load Speed].

A setting is possible from 0 to 105% of full-scale value.




If Speed Change Load is detected, even if it has not reached the free run distance, the
speed will change to Load Speed.



Chapter 6: System Operation

Speed

[20]

Freerun Distance

[54]

Recovery

Time

[50] Initial Speed

[42] Crossover Distance

Or

[14] Speed Change Load

[40]

Initial Time

[22]

Standard

Distance

Or

[13] Load

[53] Load Speed

[52] Slowdown

Speed

[41] Freerun

Speed

[53] Return Speed

Time/
Distance

Speed

[14]

Speed Change Load

[54]

Recovery
Time

[50] Initial Speed

[20] Freerun Distance

[40]

Initial Time

[22]

Standard

Distance

Or

[13] Load

[53] Load Speed

[41] Freerun

Speed

[53] Return Speed

Time/
Distance

Advertising