enFORCE

Operation Manual

6.3.4 Real Time Display Mode

The following data is displayed on the screen in the Real Time Display Mode.
The [D-NO] changes by pressing the [↑] and [↓] buttons.

0: Load

Value

Display

Displays present load applied to the load transducer in real time.

1: Load Voltage Value Display

Displays the present load signal voltage applied to the load transducer in real time.

2: Maximum Load Value Display

Displays the peak load measured from the last time the display was switched to this
mode. This is reset when leaving Real Time Display Mode.
This value can be held for 1 minute by pressing the [SET] button.

3: Distance Moved Display

Displays the absolute distance from the home position.

4: Electric Thermal Value

Displays the present electric thermal value.

5: Current

Value

Displays the present current value.
The maximum amplifier current value is 1023.

6: Resolver Position Data Display

Displays the position (in pulses) of the resolver at the present time.

7~: In-house Adjusting Display

Displays the in house adjustment value.


D-NO」 「DATA


Load value Display



Load Voltage Value Display


Maximum Load Value Display








D-NO DATA D-NO

DATA

0

Load Value Display

4

Electric Thermal Value(Overheat when 100)

1

Load Voltage Value Display

5

Current Value( Max 1023 )

2

Maximum Load Value Display
(Maximum Value Hold)

6

Resolver Position Data Display(0~4093)

3

Distance Moved Display

7~ FEC

use

only

Chapter 6: System Operation

0

1

2

n

[↑],[↓]

Button

D-NO

: 1 figure