A Step Press is a press operation that is done in multiple phases using multiple parameters.
This operation works best when used in conjunction with the “Keep Load” Return Operation. For
best results set up as follows:

ƒ

For a smooth curve, set [18: Crossover Load] equal to the previous step’s

[13: Standard Load].

ƒ

Turn On the Self Check Off signal before starting each cycle.

ƒ

After the end of each phase, start the next phase as soon as possible. Because

load recovery is not used, the press motor will turn off and the press will begin
releasing the load gradually.

The present load value will be fixed to 0 point and operate unless the
SELF-CHECK signal is turned OFF for this operation.

*There is a possibility to destroy the equipment.
This press can be done with the F type tool but make sure not to
overload.


It is recommended that, if the return of the press is done with a parameter, use Distance
Control.
However, if Standard Distance is set to 0 without a return operation, the press will reject
because the Distance Low value is zero (a value less than zero is not possible).
Refer to the following for setting up a Return Parameter. Adjustments can be made according
to the individual application.

Data Number 00 is set to 0001 → set to distance control
Data Number 20 is set to 0.0 → distance low value is 0mm
Data Number 21 is set to 2.0 → distance high value is 2mm
Data Number 22 is set to 1.0 → standard distance is 1mm
Data Number 23 is set to 3.0 → 1ST distance is 3mm
Data Number 24 is set to 2.0 → CROS distance is 2mm
Data Number 60 is set to 5.0 → free run distance is 5mm

(set larger if speed causes over run)

Data Number 62 is set to 00.0 → Operation Finish Return Position is 0mm

*All other data needs to be set to complete the parameter setup (speed, time, etc.).