background image

PAGE 4-7

enFORCE

Operation Manual

4.5 Motor Power-Resolver Connections

The motor connector provides control power to the motor.
The resolver connector handles the signals that define the rotation of the motor. The controller
provides a signal to the winding of the rotor. As the rotor spins, two sets of stators, electrically
shifted 90 degrees, generate a sine wave and a cosine wave signal. Both signals are processed by
the controller to define position and speed of the motor.
The signals for the motor and resolver are contained in one cable. See Section 4.13 and
Appendix A for connecting cable part numbers and specifications.


RESOLVER

Wiring Chart

1: (R1) Rotor

6: (R2) Rotor

2: (S2) Stator

7: (S4) Stator

3: (S1) Stator

8: (S3) Stator

4: Not Used

9: Shield

5: Not Used

10: Not Used


Mating Connector

Manufacture:

Molex

Housing Part No.:

39-01-2105

Contact Part No.:

39-00-0047 (Qty.-7)


MOTOR

Wiring Chart

SAN3-24S, 40S

1: Frame Ground

2: Not Used

3: W Phase

4: V Phase
5: U Phase

SAN3-120S (Shown Below)

1: Frame Ground

6: Frame Ground

2: Not Used

7: Not Used

3: W Phase

8: W Phase

4: V Phase

9: V Phase

5: U Phase

10: U Phase

Mating Connectors

SAN3-24S, 40S

Manufacture:

AMP

Housing Part No.:

1-178288-5

Contact Part No.:

1-175218-3 (Qty.-4)

SAN3-120S

Manufacture:

AMP

Housing Part No.:

1-178289-5

Contact Part No.:

1-175218-3 (Qty.-8)


Chapter 4: System Setup and Wiring

1
2
3
4
5

B A

SAN3-120