Load rise detection (method 2 - type 2), Enforce – FEC DSP1500 (SAN3) User Manual

Page 91

Advertising
background image

PAGE 6-29

enFORCE

Operation Manual

Load Rise Detection (Method 2 – Type 2)

This Load Control press method allows judgment of a distance (DS) at a given load
[18: Crossover Load] and press rate [33: Rate 2 High].
Type 2 Control is active if [22: Standard Distance] is set to 0.
Upon start of cycle, the press will operate until it achieves [13: Standard Load]. During
the press cycle, as soon as [18: Crossover Load] is achieved, a rate calculation will
begin based upon the load seen at a distance of .1mm before the [18: Crossover
Load]
distance and will continue to be calculated every .1mm until [33: Rate 2 High] is
exceeded. During the press cycle, checks are performed for “1

ST

Judgment Zone”, 1

ST

Rate, Load, Distance, 1

ST

Time and 2

ND

Time. If any of these values are compromised,

the press will stop and return as programmed. Final Judgment is based on the distance
where the rate exceeds [33: Rate 2 High] after [18: Crossover Load] has been
achieved.
(See corresponding sections for Time, Rate, 1

ST

Zone and Speed explanations.)







ƒ

[33: Rate 2 High] is a “control” function and is not used for judgment.

ƒ

If “1

ST

Judgment Zone” is not used, set [15: 1

ST

Load] to [10: CAL Load] and

[23: 1

ST

Distance] to a minimum of [21: High Distance].

ƒ

Review Speed Section explanations and cautions when setting [15: 1

ST

Load], [14:

Speed Change Load], [24: Crossover Distance] and [20: Freerun Distance].

ƒ

If 1

ST

Rate is not used, set judgment windows wide open; low value of 0 and

maximum high value. Also, if 1

ST

H/L Check is not being used, set [17: Threshold

Load] to [10: CAL Load].

Chapter 6: System Operation

Load

Distance

High

Load Limit is set to

1.1 x [10] Calibration Load

[11] Low Load Limit

[13] Standard Load

[15] 1

ST

Load

[14] Speed Change Load

[17] Threshold Load

[20]

Low

Distance

[21]

High

Distance

[41]

1

ST

Time

[42]

2

ND

Time

1

ST

Rate

[23]

1

ST

Distance

1ST Judgment Zone

Final Judgment Zone

(DS)

Judgment

Distance

[18] Crossover Load

[12] High Load Limit

[18] Crossover Load

(

DS) - .1mm

(

DS) + .1mm

(DS)

[33] Rate 2 High

[24]

Crossover

Distance

Advertising