Operation finish modes – FEC DSP1500 (SAN3) User Manual

Page 99

Advertising
background image

PAGE 6-37

enFORCE

Operation Manual

ƒ

Return

After both an ACCEPT or REJECT judgment, the press will move to the position set in
[62: Return Position].

ƒ

[ACCEPT] Return, [REJECT] No Return

When the judgment is an ACCEPT, the press will move to the position set in
[62: Return Position].
When the judgment is a REJECT, the press will stop and the load will be released.

ƒ

[ACCEPT] No Return, [REJECT] Return

When the judgment is an ACCEPT, the press will stop and the load will be released.
When the judgment is a REJECT, the press will move to the position set in [62: Return
Position]
.

ƒ

Jog Return

During the Return Operation, if the START (Operation Start Signal) is turned OFF, the
operation will stop and if it is turned ON, the operation will start from the position where
the press ram stopped.

ƒ

Keep Load

When the judgment is an ACCEPT, the operation will stop at the standard load or
distance position without the load being released.
When the judgment is a REJECT, the load will be released to near zero and stop.
This Mode is very useful when used in “Step Press” operations. See “Step Press
Operation” on page 6-45 for explanation and setup

ƒ

Load Ignore Return

After both an ACCEPT or REJECT judgment, the press will ignore any load built up in
the cylinder and return to the position set in [62: Return Position].

When the system is returning the cylinder in normal operation, any load
will be released before returning to [62: Return Position]. If the cylinder
reaches [62: Return Position] and it still has load, it will pass the
[62: Return position] and go to the Home Position (zero position).
This Return Method ignores the cylinder load while returning.

ƒ

No Return

After both an ACCEPT or REJECT judgment, the press will stop and the load will be
released.

In No return mode, when a load is being detected, the releasing
operation of the load is done until the load is almost zero, but the press
will not return to the operation finish return position.
If you want to stop the operation with the press on the target position
without releasing the load, select the Keep Load Operation.













Chapter 6: System Operation

Operation Finish Modes

Advertising