enFORCE

Operation Manual

6.4.5.2 Work Parameters: Parameter Number 0 1 to 3 2

Load

Settings

Distance

Settings

Rate

Settings

Time

Settings

Speed

Settings

Special

Settings

¾

Data Number

00

Operation ModeOperation MethodOperation Step

Operation Finish Mode

This data field will set the operation method, operation step and operation finish mode.


□ 0 □ □

Operation Method

0: Load Control

1: Distance Control

2: Load Control – Specified Point Load Judgment /

Load Rise Detection

3: Load Control – Time Controlled Press

4: Load Control – Load Drop Detection (Delta f falling)

5: Load Control – Specified Range Peak Load Judgment

6: Load Control – Load Drop Detection (Point Stop)

7: Distance Control – With Load Limit


Operation Step

0: 1 Step Operation SNUG Distance Count

1: 1 Step Operation

3: 1 Step Operation 1ST H/L Check

Operation Finish Mode

0: Return

1: [ACCEPT] Return, [REJECT] No Return

2: [ACCEPT] No Return, [REJECT] Return

3: Jog Return

4: Keep Load

5: Load Ignore Return

8: [ACCEPT] and [REJECT] No Return



*For further detailed operation mode instruction, see the following items.

Chapter 6: System Operation