enFORCE

Operation Manual


¾

Data Number 15 [1

ST

Load]

¾

Data Number 23 [1

ST

Distance]

ƒ

Ending point of calculation of 1

ST

Rate.

ƒ

In a 2 step operation, ending of 1

ST

step.

A setting is possible from 0 to 105% of full-scale value.

These two settings may be used together to detect foreign substances (early load).
If the press reaches [15: 1

ST

Load] before exceeding [23: 1

ST

Distance], a “1

ST

Rate Low”

reject will occur and press operation will stop.


¾

Data Number 16 - SNUG Load

ƒ

The starting point of calculation of [22: Standard Distance]. If set to 0, distance is

calculated from start.

A setting is possible from 0 to 105% full-scale value.

For example, if [16: SNUG Load] is set to 1KN and [22: Standard Distance] is 10mm:


















The distance data that is effected by [16: SNUG Load] is [22: Standard
Distance] and [24: Crossover Distance]. All other distance data uses the
[62: Return Position] value.

Chapter 6: System Operation

Load

Distance

SNUG

KN

10

mm

Judge Load

1

ST

Judgment Zone

[1

ST

Rate Low]

Load

Distance

[15] 1

st

Load

[23] 1

st

Distance

[1

ST

Judgment]