PAGE 6-13

enFORCE

Operation Manual

Item

Parameter

Number

PARM

Data

Number D-

No

DATA

00

00

Load

unit

number

:KN <No change>

00

01

SP version/copy between parameter <No change>

00

02

Amplifier Version <No change>

00

03

Function Version <No change>

00

04

Off

Set

Load

[KN]

00

05

Full Scale Extended Length [mm]

00

06

Free Run Current Limit 0~1023

00

07

Home Position Off Set [mm]

00

08

Near Origin Sensor Availability/Bank Change Enable

00

09

Home position search time out 0.1[sec] unit

00

0A

Distance

Decimal

0: NONE,1:0.1,2:0.01

00

0B

Free Run Distance Limit/Load Transducer Availability

00

0C

Current

Load

Conversion

Ratio [%]

00

0D

Stroke Distance Limit/Recovery Time Decimal Point

00

0E

MANUAL

Speed [mm/sec]







System

00

0F

Option/Speed Decimal Point

00

10

Tool

Number

00

11

Tool

CAL

Load

[KN]

00

12

Tool CAL Voltage [V]

Tool

Data

00

13

Tool Zero Load Voltage [V]

<No change>

00

14~1A

In

Home

Control

Data

Tool Type

00

20

Tool

Number

01~32

00

Operation Mode (Operation Method+Operation Step+Operation Finish Mode)

01~32

10

Full-Scale

Load

[KN]

01~32

11

Minimum

Load

Value [KN]

01~32

12

Maximum

Load

Value [KN]

01~32

13

Standard

Load [KN]

01~32

14

Speed

Change

Load

[KN]

01~32

15

1 ST Load [KN]

01~32

16

SNUG Load [KN]

01~32

17

THRESHOLD

Load [KN]

Load

01~32

18

CROS

Load [KN]

01~32

20

Minimum Distance Value [mm]

01~32

21

Maximum Distance Value [mm]

01~32

22

Standard

Distance

[mm]

01~32

23

1ST

Distance

[mm]

Distance

01~32

24

CROS

Distance [mm]

01~32

30

Minimum

Rate

1 [KN/mm]

01~32

31

Maximum

Rate

1 [KN/mm]

01~32

32

Minimum

Rate

2 [KN/mm]

Rate

01~32

33

Maximum

Rate

2 [KN/mm]

01~32

40

Initial

Time [sec]

01~32

41

Maximum

1

ST

Time [sec]

Time

01~32

42

Maximum

2

ND

Time [sec]

01~32

50

Initial

Speed [mm/sec]

01~32

51

Free Run Speed [mm/sec]

01~32

52

Slow Down Speed [mm/sec]

01~32

53

Load

Speed

[mm/sec]

Speed

01~32

54

Return

Speed [mm/sec]

01~32

60

Free

Run

Distance [mm]

01~32

61

Recovery

Time

[sec]

01~32

62

Operation Finish Return Position [mm]

01~32

63

∆f [KN]

Special Setting

01~32

64

Distance

Off

Set [mm]

Chapter 6: System Operation