PAGE 6-23

enFORCE

Operation Manual

¾

Data Number

0B

Free Run Distance LimitLoad Transducer Availability

This data field sets the maximum free run distance and availability of the load transducer.

□ □ □ □

Load Transducer Availability

0: With Load Cell

1: Without Load Cell

Free Run Distance Limit

If you set 200, the free run distance will be up to 200mm.

*Example: If the load transducer is available and the free run distance limit is 200mm, the
setting will be 2000.

¾

Data Number

0C

Current Load Conversion Ratio (percentage)

This data field sets the conversion ratio (as a percentage) of current control without the
load transducer.

*Normally it is set to 100(%).

¾

Data Number

0D

Distance Stroke LimitRecovery Time Decimal Point

It sets the maximum distance stroke allowed (except for free run distance) and decimal
point of the recovery time.


□ □ □ □

Recovery Time Decimal Point

0: X.X, 1: no decimal point

Distance Stroke Limit

If you set 200, distance settings other than free run distance will
be limited to 200mm.

*Example: If the stroke distance limit is 200mm and there is no decimal point required,
the setting will be 2001.

¾

Data Number

0E

Manual Speed

This data field sets the speed of MANUAL operations. The speed of the [home position
search], [home position return] and [high speed jog] is set to this speed.
*The maximum speed of the [home position search] is 10mm/sec.

The speed of the [middle speed jog] is 1/10 of the set value or the slowest speed of
the attached tool.
The speed of the [slow speed jog] is 1/100 of the set value or the slowest speed of the
attached tool.

¾

Data Number

0 F

Option / Speed Decimal Point / RS232 Data Format


□ □ □ □

Speed Decimal Point
0: XXXX (no decimal point), 1: XXX.X, 2: XX.XX

Do not change the setting unless it is necessary
because the speed decimal point is fixed for each
tool when shipped.

RS-232C Equipment Data Format Setting

0: Printer 1: Monitor 2: LVDT(digital gauge)

Brake Option

0: No brake (motor uses dynamic brake) 1: With Brake

If brake option is set, system will automatically be
set to SERVO OFF mode after the operation has
finished.

Special Specification

0: Normal
1: SAN2 Compatible Mode
2: The result data will not be reported for parameter number 32.

(For systems with Return function set on parameter 32)

Chapter 6: System Operation

Advertising