FEC DSP1500 (SAN3) User Manual

Page 84

Advertising
background image

PAGE 6-22

enFORCE

Operation Manual

¾

Data number

08

Near Origin Sensor AvailabilityBank Select Enable


□ □ □ □

0: No Near Origin sensor (Default)

1: Near Origin sensor attached (on presses 10 ton and larger)

2: Bank Select enable (enable output signal banks 2 & 3)


0: Enable Distance High Limit Stop (Default)

1: Disable Distance High Limit Stop


0: 0.1mm distance sampling

1: 0.01mm distance sampling

2: 0.005mm distance sampling

Operation of setting bank change

OUT DATA Banks can be selected by PIN number 9: NEAR ORIGIN/BANK 1 or
11: BANK 0 signals of the PLC I/O Connector.

See Section 4.7 “External Control Signal Connection” for further details.

Allow a minimum of 20ms to read the Bank 0 and Bank 1 Echo Outputs
when using the Data Bank Select signals

¾

Data number

09

Home Position Search Time Out

It sets the time limit of the home position search operation.
*If the operation has not finished within the time limit an abnormal will occur.

¾

Data number

0A

Distance Decimal / Deadman / Data Speed / Special Setting


□ □ □ □

Distance decimal
0: No decimal, 1: X.X, 2: X.XX
*This is factory preset. Do not change unless necessary.

You need to re-input the data if changing the distance
decimal because the decimal point of all the distance-
related data will be changed.

0: Normal Operation (Deadman Mode Disabled)

1: Home Positioning function is in Deadman Mode

2: Automatic Return function is in Deadman Mode

3: Home Positioning

&

Automatic Return is in Deadman Mode

0: RS-485

9600bps RS-232C

9600bps

1:

19200bps 9600bps

2: 38400bps 9600bps

3: 9600bps 19200bps

4:

19200bps 19200bps

5:

38400bps 19200bps

6:

9600bps 38400bps

7:

19200bps 38400bps

8:

38400bps 38400bps

*Power must be cycled for these changes to take effect.

0: No output function(rate supervise performed)

1: Sets Pin #34 option output ON 1mm before the standard distance

9: Sets Pin #34 option output ON 9mm before the standard distance

*Using settings 1-9 also enables the Timing signal (Pin #33).

Distance data is set up in Param. 1-32, D-No. 30, 31, 32 and 33.

30: Advance ON Distance 31: Advance OFF Distance

32: Return ON Distance

33: Return OFF Distance

Chapter 6: System Operation