A5_*] - servo amplifier response errors – FEC DSP1500 (SAN3) User Manual

Page 124

Advertising
background image

PAGE 8-8


enFORCE

Operation Manual

8.6 Servo Amplifier Response Errors [ A5_* ]

Code A5_0 - SERVO AMPLIFIER REPLY ERROR / NO REPLY FROM RESOLVER

The controller is attempting to turn the motor, but is not receiving any signals back from the
resolver to indicate that the tool is actually turning.

CAUSE:
1. The motor/resolver cable is damaged or not connected
2. When the resolver, motor, or the controller malfunctions.
3. If there is excessive binding in the transmission or the press shaft assembly keeping the

motor from turning.

4. When running short cycle times the brake reaction time may not be fast enough causing the

brake to drag during the first few milliseconds of the press cycle.

5. If switching Data Banks, brake engages (turns off).

RECOVERY:
1. Verify that the motor cable is connected and not damaged.
2. Connect all spare tool cables to the existing tool.
3. Exchange tool and/or controller with known working units. Reinitialize the system after

exchanges.

4. Inspect and correct any binding in the transmission or press shaft.
5. The brake is designed to be used for maintenance, not for control. Set Parameter 00, Data

No. 0F to “No Brake” (this allows motor to control holding of press). See Page 4-26 for brake
setup.
If brake must be used for control on short cycle time applications, incorporate a timer to delay
the start until the brake has time to react.

6. When switching Data Banks the meaning of the BUSY signal will change. Provide a means to

keep the brake disengaged (on) while changing Data Banks. See Page 4-26 for brake setup.































Chapter 8: Troubleshooting