Chapter 4: Installation & Wiring

4.4 Input Power Connection

An auto sensing power supply allows for input power in the range of 100 ~ 220VAC single phase,
50/60 hertz. Adequate circuit protection must be provided. Recommended conductor size should be
a minimum of #16AWG.

Wiring Chart

4: 100 ~ 220VAC +/-15%
3: 100 ~ 220VAC +/-15%
2: No Connection **
1: Frame Ground


Mating Connector

Manufacture: Amp
Housing Part No.:

1-178128-4

Contact Part No.:

1-175218-3 (Qty.-3)

** To standardize components, FEC cable
part #FEB-1280 may be used due to the fact
that pin #2 is not connected internally.

4.5 RS485 Connection

The Main Unit uses an RS485 port to perform the communication operations with the DSP1500
Servo (SAN) Controllers. This port has two channels CH1 and CH2. CH1 is dedicated to handle all
preset data upload and download, pressing results monitoring and collection. Channel CH2 is a high
speed connection to all DSP1500 Servo Controllers. It controls all required commands to perform
the pressing cycle.

RS485 port specifications (RJ45)
Speed

9600, 19200, 38400 baud

Cable

Std Cat 5 Ethernet

Maximum number of
connected devices

31

Protocol Proprietary
Operating Voltage

RS485 Standard

RS485 Wiring





Pin Signal Name

Channel

1 TX+ / RX+

CH1

2 TX- / RX-

CH1

3 RX+

CH2

4 TX-

CH2

5 TX+

CH2

6 RX-

CH2

7 GND

8 GND

1

8

4

3

2

1