5.3 Discrete I/O Interface
The Discrete I/O Interface is commonly used for direct connect PLC applications. Although, each
individual DSP1500 Servo Controller can also be wired directly to a PLC through its own PLC I/O
port (for individual control).
5.3.1 Sinking Type (NPN)
Discrete I/O (Sinking Type) Board Specifications
Operating Voltage
24 VDC
Maximum current (outputs) 200 ma
Logic True
Low
(Sinking)
Mating Connectors
PLC-IN
Connector: Honda #MR-34F
Housing: Honda #MR-34L
PLC-OUT
Connector: Honda #MR-34M
Housing: Honda #MR-34L
CN3
CN4
12
1
13
23
22
34
34
23
13
1
12
22