PAGE 5 - 4

Chapter 5: Control Interfaces

5.2.2 Jog (Manual) Operation


Signal Timing

JOG

OFF

ON

START

OFF

ON

RETURN

OFF

ON

(OPERATION)

Jog

Advance

Jog

Return

BUSY

OFF

ON

READY

OFF

ON

Press Selection (Press No. 4)

PRESS SEL. 0

OFF

ON

PRESS SEL. 1

OFF

ON

PRESS 0 SEL’D

OFF

ON

PRESS 1 SEL’D

OFF

ON




ƒ

The Jog input must be high (on) to perform manual operations.

ƒ

While the Jog input is active, a Start input will advance the press as long as the signal is

maintained.

ƒ

While the Jog input is active, a Return input will return the press as long as the signal is

maintained.

ƒ

It is recommended when changing press selections that the Select outputs be used to verify that

the desired press number has been changed before issuing a movement signal (Start, Return).
Delay from Press Select input to Press Selected output is approximately 5ms.

ƒ

The Jog operations are used to move the press under “no load” conditions unless a Bonding

type press is used. Attempting to press a part or move the press under load conditions while
using a Fitting type press may cause an abnormal. If Jog operations are required under “load”
conditions, use a Bonding type press.
















Allow a minimum of 20ms to interlock the Press
Select Command and the Start / Return signal.